Material Safety Data Sheet
Industrial Oil Fortifier
_____________________________________________________________
Section 1 - Product Identification
Product Name: Boundary Friction Control Industrial
Product Type: Petroleum Based Oil Fortifier
Chemical Name: Mixture
Emergency Phone Number: 1-800-844-9327
_____________________________________________________________
Section 2 - Hazardous Ingredient Information
Component CAS # OSHA PEL ACGIH TLV SARA 313 List
Petroleum Naphtha Aromatic 64742-94-5 100 PPM 100 PPM NO
All other base oils and additives are non hazardous
Specific chemical identities withheld claiming trade secret.
______________________________________________________________________
Section 3 - Health Hazards
Inhalation: Negligible hazard at ambient temperatures.
Inhalation: Minimal toxicity. Harmful if aspirated into lungs.
Skin Contact: Low order of toxicity.
Eye Contact: Irritating, may injure eye tissue if not removed promptly.
______________________________________________________________________
Section 4 - Emergency First Aid Procedures
Eye Contact: Immediately flush eyes with large amounts of water for at least 15 minutes. Get prompt medical attention.
Skin Contact: Flush with water, use soap if available. Remove contaminated clothing, including shoes, after flushing has begun.
Inhalation: Using proper respiratory protection, immediately remove the affected victim from exposure. Administer artificial respiration if breathing has stopped. Call for prompt medical attention.
Ingestion: Do not induce Vomiting, if individual is conscious, give individual water or milk to dilute stomach contents. Keep warm and quiet. Get prompt medical attention.
Do not attempt to give anything by mouth to an unconscious victim.
______________________________________________________________________
Section 5 - Chemical and Physical Properties
Appearance: Clear amber liquid
Odor: Mild sweet petroleum odor
Vapor pressure: Negligible at ambient temperatures
Soluble in Water: Insoluble
Specific Gravity: 1.212 @ 68 Degrees F
Boiling Point: Greater than 400 degrees F IBP
______________________________________________________________________
Section 6 - Fire and Explosion Hazard
Flash Point: 325 Degrees F (COC)
Flammable Limits: Not available
NFPA (704) Health - 2 KEY 0=Minimal 1=Slight 2= Moderate
Flammability - 1 3= Serious 4= Severe
Reactivity - 1
Extinguishing Media: Dry chemical, water spray (fog), foam or CO2
Firefighting Procedures: Use water to cool fire exposed surfaces and protect personnel. Isolate "fuel" supply from fire. Respiratory and eye protection required for fire fighting personnel. Avoid spraying water directly into containers due to danger of boil over.
Hazardous Combustion Products: Fumes, smoke and oxides of sulphur, carbon and nitrogen.
______________________________________________________________________
Section 7 - Spill Control Procedure
Land Spill: Eliminate sources of ignition. Prevent additional discharge of material. For small spills, implement clean up. For large spills, implement clean up, keep the public away and notify authorities. Prevent liquid from entering waterways. Contain spill with inert material. Dispose of in accordance with local, state and federal regulations.
Water Spills: Prevent additional discharge of material. Remove from surface by skimming or proper absorbent.
______________________________________________________________________
Section 8 - Reactivity Data
This product is stable and hazardous polymerization will not occur. Incompatible with strong oxidizing agents. Avoid contact.
______________________________________________________________________
Section 9 - Protection Precautions
Personal Protection: For open systems where contact is likely, wear long sleeves, chemical resistant gloves and chemical goggles. Where contact may occur, wear safety glasses with side shields.
Ventilation: The use of local exhaust ventilation is recommended. Provide mechanical ventilation in confined spaces.
______________________________________________________________________
The information contained herein is, to the best of Boundary Friction Controls knowledge, accurate and reliable as of the date of issuance. Boundary Friction Control does not guarantee or warranty the reliability, completeness or accuracy of the information contained herein. It is the users responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use. We do not accept liability for any loss or damage that may occur from the use of this information.